####################### mysql-test\t\sql_log_bin_basic.test ###################
|
|
# #
|
|
# Variable Name: sql_log_bin #
|
|
# Scope: SESSION #
|
|
# Access Type: Dynamic #
|
|
# Data Type: boolean #
|
|
# Default Value: #
|
|
# Valid Values: 0,1 #
|
|
# #
|
|
# #
|
|
# Creation Date: 2008-02-07 #
|
|
# Author: Rizwan #
|
|
# #
|
|
# Description: Test Cases of Dynamic System Variable sql_log_bin #
|
|
# that checks the behavior of this variable in the following ways#
|
|
# * Default Value #
|
|
# * Valid & Invalid values #
|
|
# * Scope & Access method #
|
|
# * Data Integrity #
|
|
# #
|
|
# Reference: http://dev.mysql.com/doc/refman/5.1/en/ #
|
|
# server-system-variables.html #
|
|
# #
|
|
###############################################################################
|
|
|
|
--source include/load_sysvars.inc
|
|
|
|
########################################################################
|
|
# START OF sql_log_bin TESTS #
|
|
########################################################################
|
|
|
|
|
|
##############################################################################
|
|
# Saving initial value of sql_log_bin in a temporary variable #
|
|
##############################################################################
|
|
|
|
SET @session_start_value = @@session.sql_log_bin;
|
|
SELECT @session_start_value;
|
|
|
|
--echo '#--------------------FN_DYNVARS_156_01------------------------#'
|
|
########################################################################
|
|
# Display the DEFAULT value of sql_log_bin #
|
|
########################################################################
|
|
|
|
SET @@session.sql_log_bin = 0;
|
|
SET @@session.sql_log_bin = DEFAULT;
|
|
SELECT @@session.sql_log_bin;
|
|
|
|
SET @@session.sql_log_bin = 1;
|
|
SET @@session.sql_log_bin = DEFAULT;
|
|
SELECT @@session.sql_log_bin;
|
|
|
|
|
|
--echo '#---------------------FN_DYNVARS_156_02-------------------------#'
|
|
#############################################################################
|
|
# Check if sql_log_bin can be accessed with and without @@ sign #
|
|
#############################################################################
|
|
|
|
SET sql_log_bin = 1;
|
|
SELECT @@sql_log_bin;
|
|
|
|
--Error ER_UNKNOWN_TABLE
|
|
SELECT session.sql_log_bin;
|
|
|
|
--Error ER_UNKNOWN_TABLE
|
|
SELECT local.sql_log_bin;
|
|
|
|
SET session sql_log_bin = 0;
|
|
SELECT @@session.sql_log_bin;
|
|
|
|
|
|
--echo '#--------------------FN_DYNVARS_156_03------------------------#'
|
|
########################################################################
|
|
# change the value of sql_log_bin to a valid value #
|
|
########################################################################
|
|
|
|
SET @@session.sql_log_bin = 0;
|
|
SELECT @@session.sql_log_bin;
|
|
SET @@session.sql_log_bin = 1;
|
|
SELECT @@session.sql_log_bin;
|
|
|
|
|
|
--echo '#--------------------FN_DYNVARS_156_04-------------------------#'
|
|
###########################################################################
|
|
# Change the value of sql_log_bin to invalid value #
|
|
###########################################################################
|
|
|
|
--Error ER_WRONG_VALUE_FOR_VAR
|
|
SET @@session.sql_log_bin = -1;
|
|
--Error ER_WRONG_VALUE_FOR_VAR
|
|
SET @@session.sql_log_bin = 2;
|
|
--Error ER_WRONG_VALUE_FOR_VAR
|
|
SET @@session.sql_log_bin = "T";
|
|
--Error ER_WRONG_VALUE_FOR_VAR
|
|
SET @@session.sql_log_bin = "Y";
|
|
--Error ER_WRONG_VALUE_FOR_VAR
|
|
SET @@session.sql_log_bin = TRÜE;
|
|
--Error ER_WRONG_VALUE_FOR_VAR
|
|
SET @@session.sql_log_bin = ÕN;
|
|
--error ER_PARSE_ERROR
|
|
SET @@session.sql_log_bin = OF;
|
|
--Error ER_WRONG_VALUE_FOR_VAR
|
|
SET @@session.sql_log_bin = ÓFF;
|
|
--Error ER_WRONG_VALUE_FOR_VAR
|
|
SET @@session.sql_log_bin = '¹';
|
|
--Error ER_WRONG_VALUE_FOR_VAR
|
|
SET @@session.sql_log_bin = NO;
|
|
|
|
|
|
--echo '#-------------------FN_DYNVARS_156_05----------------------------#'
|
|
###########################################################################
|
|
# Test if setting global sql_log_bin gives error, #
|
|
# and there is a deprecation warning on reading it. #
|
|
###########################################################################
|
|
|
|
--Error ER_INCORRECT_GLOBAL_LOCAL_VAR
|
|
SELECT @@global.sql_log_bin;
|
|
--Error ER_LOCAL_VARIABLE
|
|
SET @@global.sql_log_bin = 0;
|
|
--Error ER_INCORRECT_GLOBAL_LOCAL_VAR
|
|
SELECT @@global.sql_log_bin;
|
|
--Error ER_LOCAL_VARIABLE
|
|
SET @@global.sql_log_bin = 1;
|
|
|
|
--echo '#----------------------FN_DYNVARS_156_06------------------------#'
|
|
#########################################################################
|
|
# Check if the value in GLOBAL Table contains variable value #
|
|
#########################################################################
|
|
|
|
--disable_warnings
|
|
SELECT count(VARIABLE_VALUE) FROM performance_schema.global_variables WHERE VARIABLE_NAME='sql_log_bin';
|
|
--enable_warnings
|
|
|
|
--echo '#----------------------FN_DYNVARS_156_07------------------------#'
|
|
#########################################################################
|
|
# Check if the value in GLOBAL Table matches value in variable #
|
|
#########################################################################
|
|
|
|
--disable_warnings
|
|
SELECT IF(@@session.sql_log_bin, "ON", "OFF") = VARIABLE_VALUE
|
|
FROM performance_schema.session_variables
|
|
WHERE VARIABLE_NAME='sql_log_bin';
|
|
--enable_warnings
|
|
SELECT @@session.sql_log_bin;
|
|
--disable_warnings
|
|
SELECT VARIABLE_VALUE
|
|
FROM performance_schema.session_variables
|
|
WHERE VARIABLE_NAME='sql_log_bin';
|
|
--enable_warnings
|
|
|
|
--echo '#---------------------FN_DYNVARS_156_08-------------------------#'
|
|
###################################################################
|
|
# Check if ON and OFF values can be used on variable #
|
|
###################################################################
|
|
|
|
SET @@session.sql_log_bin = OFF;
|
|
SELECT @@session.sql_log_bin;
|
|
SET @@session.sql_log_bin = ON;
|
|
SELECT @@session.sql_log_bin;
|
|
|
|
--echo '#---------------------FN_DYNVARS_156_09----------------------#'
|
|
###################################################################
|
|
# Check if TRUE and FALSE values can be used on variable #
|
|
###################################################################
|
|
|
|
SET @@session.sql_log_bin = TRUE;
|
|
SELECT @@session.sql_log_bin;
|
|
SET @@session.sql_log_bin = FALSE;
|
|
SELECT @@session.sql_log_bin;
|
|
|
|
##############################
|
|
# Restore initial value #
|
|
##############################
|
|
|
|
SET @@session.sql_log_bin = @session_start_value;
|
|
SELECT @@session.sql_log_bin;
|
|
|
|
###############################################################
|
|
# END OF sql_log_bin TESTS #
|
|
###############################################################
|